GB
Halogen floodlight
Operation and maintenance manual
Dear valued customer,
Thank you for purchasing our floodlight.
Before operating the floodlight, please read the following instructions for use carefully and keep
them in a safe place for future reference.
Proper Use
The floodlight is spray-protected, IP44 and for use outdoors
The floodlight conforms with the appropriate European CE regulations.
General Safety Instructions
• must always be placed at least 1m away from the surface being illuminated – in particular, the
power cable must not be illuminated or come into contact with the metal housing – maintain the
specified minimum clearances.
• must always be given sufficient time to cool down – the floodlight housing can get extremely hot –
the power supply to the floodlight must always be disconnected and locked out before servicing,
e.g. for bulb replacement or cleaning.
• must only be used on flat, stable surfaces.
• use only with a sufficiently protected 230V~ installation.
• must not be used in rooms that represent an explosion hazard (e.g. cabinetmaker's workshop,
painting operation, or similar).
• must not be used in the immediate vicinity of flammable materials.
• must not be set up in the immediate vicinity of pools, fountains, ponds, or similar bodies of water.
must not be immersed in water or other liquids.
• must not be immersed in water or other liquids.
• must not be operated with wet hands; never look directly into the light source.
• must never be covered.
• must never be operated with an open housing, missing or damaged wiring compartment, or
missing or damaged lens.
• must never be sprayed or cleaned using a steam pressure cleaner since this can damage the
insulation and seals.
• must never be repaired by the user. Repairs must only be carried out by the manufacturer or an
authorized service representative.
Technical Data
• Typ 7040115A:
Output: max.150W
• Typ HFGT120AW:
Output: max.150W
• Typ 7040150A:
Output: max. 500W
• Typ HFGT230AW:
Output: max. 230W
• Typ 7040110A:
Output: max. 1000W
• Voltage: 230V~, 50Hz
• Protection class IP44
6
All manuals and user guides at all-guides.com
Illuminant Installation
• Loosen the screw on the top of the floodlight and swing the lens forward.
• Remove the illuminant from the packaging.
• Avoid touching it with bare hands since this causes grease stains which lead to overheating. Use
a clean, dry, lint-free cloth.
• Insert one end of the illuminant into the socket, press against it, and insert the other end of the
illuminant into the socket. Ensure that the socket is not damaged.
• Then close the lens and retighten the screw.
Installing
Installation may only be carried out by trained professionals according to the applicable installation
regulations. Contact a licensed electrician.
ATTENTION!! Before installation, the power supply must be disconnected and locked out.
• Loosen the screws on the side of the housing and remove the mounting brackets.
• Install the mounting brackets to a suitable surface – always follow the installation location requi-
rements listed under "General Safety Information".
• Reattach the floodlight housing to the mounting brackets but do not tighten the screws fully.
• Loosen the screws on the back of the junction box and remove the cover.
• Remove the cable guide screw connection and guide it over the connecting cable – the screw
connection thread must face in the direction of the cable end.
• Loosen the cable grip screws and remove the cable grip.
• Guide the screw connection seal over the cable as well, and then insert the cable into the junction
box. Ensure the seal is seated in the cable guide correctly – if the connecting cable is too thin,
the cable guide must be additionally sealed.
• Connect the wires according to Figure 5.
• Tighten the cable guide screw connection, install the cable grip, and tighten the screws.
• Install the junction box cover and tighten the screws.
Setting the Floodlight Direction
Loosen the screws on the sides of the mounting brackets, adjust the floodlight direction, and then
retighten all screws.
Replacing the Illuminant
You can find the technical data for the illuminant under "Technical Date" or on the type plate
attached to the floodlight housing.
• Disconnect and lock out the power supply to the floodlight. Allow the floodlight to cool down
sufficiently!
• Loosen the screw for the lens on top of the floodlight and swing the lens forward.
• Remove the illuminant from the packaging.
• Avoid touching it with bare hands since this causes grease stains which lead to overheating. Use
a clean, dry, lint-free cloth.
• Insert one end of the illuminant into the socket, press against it, and insert the other end of the
illuminant into the socket. Ensure that the socket is not damaged.
• Then close the lens and retighten the screw.
Cleaning
• Disconnect and lock out the power supply to the floodlight. Allow the floodlight to cool down
sufficiently!
• Clean with a dry or slightly moist, clean, lint-free cloth and a mild detergent if required. Do not
use cleaners that contain abrasives or solvents.
GB
7