SAFETY AND OPERATING INSTRUCTIONS
4.02
TWECO
MIG-KWIK CONNECTION AND ADAPTER KIT
®
INSTALLATION
Installation of a Tweco MIG gun with a Tweco connector plug, may require an adapter kit. Choose
the correct adapter kit for your wire feeder from the Adapter Kit Listing Form No. TLAK-97 for
more detail. To install, follow the instructions furnished with the adapter kit. Figure 4 shows
the general adapter kit installation.
Receptacle
(TLAK-1 or 6TLAK-1)
1. Screw adapter plug into the receptacle and tighten.
2. Insert the adapter plug and receptacle into the wire feeder wire guideout. Tighten the
wire guide attachment screw.
3. If needed, attach a proper sized welding cable from the welding power source to the
receptacle power connection.
4. Attach a gas hose to the receptacle and to the feeder gas solenoid.
When using an adapter kit, the gas must be attached to the receptacle to provide
gas to the MIG gun. If the feeder gas supply is attached to the feeder wire guideout
block, it must be rerouted to the receptacle.
5. Insert the MIG gun rear connection plug into the receptacle and tighten the attachment
screw.
6. Attach the control wire plug assembly to the wire feeder MIG gun control circuit. Then
plug the flat double female plug into the MIG gun.
The gun should now be installed and ready to feed wire as recommended by the feeder
manufacturer.