Commissioning The Unit; Configuration Of The If-704Eth Network Addresses - Optimus IF-704ETH Manual De Instrucciones

Ocultar thumbs Ver también para IF-704ETH:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6. COMMISSIONING THE UNIT

To commission the IF-704ETH we must send configurations to it via an Ethernet connection. Accomplishing this requires a PC
equipped with a network card and connected to the unit through a switch or directly using a network cable. The PC must have the
Call Point software installed.
1. Make the connections between units.
2. Apply power to the units.
3. Via the Call Point software, configure the parameters of the IF-704ETH and send the settings to the unit.
WARNING
To send configurations to the unit requires having the unit and the PC within the same IP address range. The unit's
network addresses and those set via the configuration software must match.
By default, the network configurations of the unit are the following:
IP ADDRESS:
NETMASK:
GATETEWAY: 0.0.0.0 (without Gateway)
If you wish to assign a different network address to the equipment, other than the one established by default, refer
to the following section 6.1. Configuration of the IF-704ETH network addresses.

6.1. Configuration of the IF-704ETH network addresses

To change the unit's network settings by default, carry out the following:
1. From the PC, open a browser, enter the IP address for the unit and press
INTRO. By default the IP address is 10.1.1.1. Warning: The range of IP
addresses for the unit and the PC must match. Otherwise, the network
settings of the PC must be changed first in order to place it within the range of
the unit (for example, the PC could have an IP address of 10.1.100.152).
2. Enter the user name optimax, the password
1933 and click on the Login button
IF-704ETH version 5.0.001
IF-704ETH
10.1.1.1
255.0.0.0
R+D Department
IP Audio interface
with 4 outputs
12

Publicidad

Tabla de contenido
loading

Tabla de contenido