Connection; Power Supply; Output Zones Connection; Speakers Line Connection Without Surveillance - Optimus IF-704ETH Manual De Instrucciones

Ocultar thumbs Ver también para IF-704ETH:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5. CONNECTION

5.1. Power supply

The equipment has a 100-240VAC power input which allows the connection of the
equipment to the mains by means of the supplied cable, and if required by safety
standards, a secondary power supply input of 24 VDC.

5.2. Output zones connection

5.2.1. Speakers line connection without surveillance

IF-704ETH version 5.0.001
IF-704ETH
PRIMARY
POWER SUPPLY
24VDC
POWER SUPPLY
I924UP (not included)
ZONE 1
INPUT
AMPLIFIER
ZONA 2
INPUT
AMPLIFIER
LINE OUTPUT
SECONDARY
POWER SUPPLY
RJ45 OUTPUT "A" and OUTPUT "B" CONNECTORS PINOUT
Pin 1: AUDIO H output (HOT)
Pin 2: AUDIO C output (COLD)
Pin 3: +24 VDC input to monitoring the amplifier.
Pin 4: Not used.
Pin 5: Not used.
Pin 6: PRIORITY output contact.
Pin 7: Not used.
Pin 8:
Metal Shield:
SPEAKERS
LINE OUTPUT
ZONE 2 SPEAKERS LINE
SPEAKERS
R+D Department
IP Audio interface
with 4 outputs
Internal jumper
JP3/JP1
GND
Internal jumper
JP5/JP6
ZONE 1 SPEAKERS LINE
9

Publicidad

Tabla de contenido
loading

Tabla de contenido