Interoperabilidad Enocean - Intesis IntesisBox DK-AC-ENO-1 Manual De Usuario

Interfaz enocean para aire acondicionado daikin. compatible con todos los modelos de la gama doméstica
Tabla de contenido

Publicidad

®
IntesisBox
10.

Interoperabilidad EnOcean

Aquí se muestra una lista de los EEP admitidos tanto en transmisión como en recepción:
EEP Tx
Descripción EEP
[05-02-01]
Light and Blind Control – Application Style 1
[07-02-05]
Temperature Sensor. Range 0°C to +40°C
[07-10-01]
Temperature Sensor; Set Point, Fan Speed and Occupancy Control
[07-10-03]
Temperature Sensor; Set Point Control
[07-20-10]
HVAC Components. Generic HVAC interface. Functions: Mode, vane
position, fan speed, sensors and on/off
[07-20-11]
HVAC Components. Generic HVAC interface. Functions:
control: AC Error code, Error states and disablements
Tabla 10.1 EEP de transmisión permitidos del dispositivo
EEP Rx
EEP description
[05-02-xx]
Rocker Switch, 2 Rocker
[05-03-xx]
Rocker Switch, 4 Rocker
[05-04-01]
Key Card Activated Switch
[06-00-01]
Single Input Contact
[07-02-05]
Temperature Sensor. Range 0°C to +40°C
[07-02-06]
Temperature Sensor. Range +10°C to +50°C
[07-07-01]
Occupancy Sensor
[07-08-01]
Light, Temperature & Occupancy Sensor
[07-08-02]
Light, Temperature & Occupancy Sensor
[07-10-01]
Temperature Sensor; Set Point, Fan Speed and Occupancy Control
[07-10-02]
Temperature Sensor; Set Point, Fan Speed and Day/Night Control
[07-10-03]
Temperature Sensor; Set Point Control
[07-10-04]
Temperature Sensor; Set Point and Fan Speed Control
[07-10-05]
Temperature Sensor; Set Point and Occupancy Control
[07-10-06]
Temperature Sensor; Set Point and Day/Night Control
[07-10-07]
Temperature Sensor; Fan Speed Control
[07-10-08]
Temperature Sensor; Fan Speed and Occupancy Control
[07-10-09]
Temperature Sensor; Fan Speed and Day/Night Control
[07-10-0A]
Temperature Sensor, Set Point Adjust and Single Input Contact
[07-10-0B]
Temperature Sensor and Single Input Contact
[07-10-0C]
Temperature Sensor and Occupancy Control
[07-10-0D]
Temperature Sensor and Day/Night Control
[07-10-10]
Temperature and Humidity Sensor; Set Point and Occupancy
Control
[07-10-11]
Temperature and Humidity Sensor; Set Point and Day/Night
Control
[07-10-12]
Temperature and Humidity Sensor; Set Point Control
[07-10-13]
Temperature and Humidity Sensor; Occupancy Control
[07-10-14]
Temperature and Humidity Sensor; Day/Night Control
[07-20-10]
HVAC Components. Generic HVAC interface. Functions: Mode, vane
position, fan speed, sensors and on/off
[07-20-11]
HVAC Components. Generic HVAC interface. Functions:
control: AC Error code, Error states and disablements
[07-30-02]
Digital Input. Single Input Contact
Tabla 10.2 EEP de recepción permitidos del dispositivo
1
EnOcean Equipment Profiles (EEP) V2.0
© Intesis Software S.L. – Todos los derechos reservados
La información de este documente puede cambiar sin previo aviso.
IntesisBox es una marca registrada de Intesis Software SL
DK-AC-ENO-1/1C
1
v.1
Manual de Usuario
URL
http://www.intesis.com
email
info@intesis.com
tel
+34 938047134
rev.5
Error
Error
29 / 30

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Intesisbox dk-ac-eno-1c

Tabla de contenido