Panel Installation; Custom Panels - Subzero Classic Serie Guia De Instalacion

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Panel Installation

Custom Panels

For overlay and flush inset applications, custom door and
grille panels must be installed. The panel size is critical for
a proper fit. To verify panel requirements and dimensions,
refer to the Sub-Zero Design Guide at subzero.com/specs.
IMPORTANT NOTE: Flush inset applications require a mini-
mum 1/2"
reveal on all sides.
(13)
Finish all sides of the custom panels. They may be visible
when the door is open or through the window of glass
door models.
EXTERNAL DISPENSER
For external dispenser models, the dispenser bezel must be
removed before the custom panels can be installed.
The bezel will accommodate a minimum 3/4"
panel. Panels thicker than 3/4"
dispenser area to 1 1/8"
(including the backer and spacer
(29)
panels).
To remove the bezel:
1
Lift, rotate, and remove the grille.
Lift and remove the tray.
2
3
Remove the center posts from the push rivets, then
remove the rivets from the bottom of the control panel.
Rotate the control panel downward and disconnect the
4
wire harness.
Remove the screws from each corner of the bezel and
5
pull the bezel forward.
GRILLE
TRAY
Tray and grille removal
thick
(19)
must be routed in the
(19)
MANDREL
Dispenser bezel removal
subzero.com | 13

Publicidad

Tabla de contenido
loading

Tabla de contenido