Reset button
The reset button is used to restore output if an
overload occurs. To restore output, reduce the
loads and press the reset button.
Energy-saving switch
When the energy-saving switch is in "ON"
position, the energy saving equipment controls
the engine rotate speed according to the
connected loads. There will be good fuel
consumption and low noise.
When the energy-saving switch is in "OFF"
position, the engine will always run in rated
rotate speed no matter it is connected to the
loads or not.
Note: Please set the energy-saving switch to
"OFF" position when connect to air compressor,
sinking pump etc., because these equipments
need large starting current.
Grounding terminal
The grounding terminal is designed to prevent electric
shock by connecting it to the grounding wire. The
generating set must be properly grounded before
operation.
Combination switch
(STOP&OFF&RUN&CHOKE)
Note: One-button start and remote control start, no
function of manually close for the choke. Stop: The
stop position of the generator.
Note: After the generating set is unloaded, please run
for 3 minutes at no load to stabilize the temperature,
then stop the generating set.
Off: Fuel off without stop. This position can run out
of the remaining fuel and improve the reliability of
the generating set. Note: If you do not plan to use the
generator in the near future, please use this function,
or drain the fuel inside the carburetor through the
carburetor drain bolt.
Run: The generating set operates normally.
Choke: Close the choke.
Note: Turn to choke position to start when engine is
cold, and turn to Run position to start when engine is
hot.