Troubleshooting
Problem
Burner will not light
Sudden drop in gas flow or low flame
Flames blow out
Flare-up
Flashback (fire in burner tube, roaring
sound from burner)
The Ooni Customer Service can be reached via www.ooni.com or support@ooni.com
Nominal hourly gas consumption
Ooni Koda 16 - Outdoor Use Gas Grill
Gas Type
4wci NG
Manufacturer Address:
Ooni Limited, Unit 5, Bishopsgate Business Centre, 189 West Main Street, Broxburn, UK, EH52 5LH
10
Possible Cause
1. No gas flow
2. Coupling nut and regulator not fully
connected
3. Obstruction of gas flow
4. Disengagement of burner to valve
5. Incorrect assembly
1. Out of gas
1. High or gusting winds
1. Grease build up
2. Excessive fat in meat
3. Excessive cooking temperature
4. Excess flour on the cooking surface
1. Burner and/or burner tubes are
blocked
2. Pressure drop during ingition
Injector Size Main
Number of Burners
Burner
1
2.15mm
Prevention/Solution
1. Turn the coupling nut about one-half
to three quarters additional turn until
solid stop. Tighten by hand only - do
not use tools
2. Clear burner tube
3. Reengage burner and valve
4. Check steps in assembly instructions
1. Turn off gas control knob, wait 30
seconds and light oven. If flames are
still low, turn off gas control knob
and natural gas supply. Disconnect
regulator. Reconnect regulator and
leak test. Turn on natural gas supply,
wait 30 seconds and then light oven.
1. Turn front of oven away from wind
2. Refer to Sudden drop in gas flow
above
1. Clean oven
2. Trim fats from meat before cooking
3. Adjust (lower) temperature
accordingly
4. Brush remnant flour from cooking
surface
1. Turn gas control knob off. Clean
burner and/or burner tubes.
2. Turn off oven, ensure the tank valve is
fully open (if applicable) and relight.
Total Gas
Gas Pressure KPa
Consumption BTU
29000
1.00