Installation - Truper HIDR-1X100 Manual

Ocultar thumbs Ver también para HIDR-1X100:
Tabla de contenido

Publicidad

Installation

Mounting
• The set-up place for the equipment shall be dry and no exposed to weather with enough air flowing to get adequate
ventilation (A). The environment temperature shall not exceed 104 °F.
• Use bolts to fix the equipment to a concrete base to prevent vibration (B). The hydro pneumatic equipment shall be set
horizontally to assure perfect functioning.
• The suction and pressure lines pipes shall be fastened to the wall or floor to prevent voltage transmission to the hydro
pneumatic equipment (C).
• Use care not to damage the hydro pneumatic equipment and / or pipes due to excessive tightening of the joints.
• Use thread tape (Teflon) to seal all the joints. Leaks cause air entrance and hinder the water outlet.
Suction Line (Input)
• The suction pipe diameter shall not be smaller than the
water inlet of the hydro pneumatic equipment. If the
suction height exceeds 4 meters, use a pipe with larger
diameter.
• The suction pipe shall be completely hermetic. One side
shall be submerged into the water at least half-a -meter.
There, install a foot-valve (D). The pipe elbows shall bend
90° towards the hydro pneumatic water connection.
• The suction line shall be as short as possible because
the suctioning capacity is lower on a par with the line
increase. The suction line shall go up regularly to the
equipment to prevent air pockets.
CAUTION
If these indications are not followed,
there will be air blocks and bubbles interfering with the
hydro pneumatic proper performance.
C
F
D
Pressure Line (Outlet)
• The outlet pipe shall have a gate valve (E) to set flow
and pressure speeds required.
• Set two check valves (F). One, between the
pressurized water and the gate valve. The other,
between the water storage tank or cistern and the water
inlet.
B
Wrong
installation
A
F
E
7
ENGLISH

Publicidad

Tabla de contenido
loading

Tabla de contenido