974731.book : i97473us.fm Seite 1 Donnerstag, Februar 17, 2000 12:45 PM
Application
Operation is possible in conjunction with:
- Pressurized storage heaters
- Thermally controlled instantaneous heaters
- Hydraulically controlled instantaneous heaters
Operation with low-pressure storage heaters
(displacement water heaters) is not possible.
Specifications
• Max. flow
9.5 L/min or 2.5 gpm/80 psi
8.3 L/min or 2.2 gpm/60 psi
• Flow pressure
- min.
- recommended
- greater than 72.5 psi, fit pressure
reducing valve
• Max. operating pressure
• Test pressure
• Temperature
- max. (hot water inlet)
• Water connection
Notes:
- Major pressure differences between hot and cold
water supply should be avoided.
- To be installed according to local codes and
regulations.
- This faucet is not intended for the use with portable
appliances.
Installation
Flush pipes thoroughly.
Mount faucet on basin
See dimensional drawing fold-out page I.
Connect faucet
For this purpose the supply hoses must be connected
to the angle stops (or other supply points), see fold-out
page III, figs. [1] and [2].
The hot water supply should be connected on the left,
the cold water supply on the right side.
1
English
Connect spray hose with handspray (31 708 /
31 735 / 31 771), see fold-out page II.
(Do not use additional seals.)
- Mount spray holder (28 729) to deck.
- Insert spray hose complete with handspray (27 844)
from above through the spray holder.
- Connect spray hose to swivel connection of the
faucet.
Open cold and hot water supply and check
connections for leakage.
7.25 psi
14.5 - 72.5 psi
Maintenance
Inspect and clean all parts, replace as necessary and
145 psi
grease with special grease (order no. 18 012).
232 psi
I. Ceramic cartridge, see fold-out page II.
176 °F
Unscrew the ceramic cartridge (45 882 / 45 883)
hot - LH
using a 11/16" (17mm) fixed spanner.
cold - RH
II. Flow regulator, see fold-out page II.
Unscrew and clean flow regulator (13 954).
III. Diverter, see fold-out page II.
1. Pull off cast spout.
2. Pull out the diverter (07 970) and clean.
Assemble in reverse order.
Replacement parts, see fold-out page II ( * = special
accessories).
Care
Instructions for care of this faucet will be found in the
Limited Warranty supplement.

Publicidad

loading

Este manual también es adecuado para:

31 05631 73531 05731 06131 77131 708 ... Mostrar todo