Locate Dispenser
1. Place dispenser upright.
2. Locate dispenser on a hard and level surface in a cool shaded
location near a grounded wall outlet.
Notice: Do NOT plug in power cord yet.
3. Position dispenser so the back is at least 20cm from wall and
there are at least 20cm of clearance on both sides.
Assemble
1. Remove drip tray from door and place the grid on top.
2. Snap drip tray and grid assembly into door.
Install Water Bottle
1. Open dispenser door.
2. Place probe assembly on probe hanger.
3. Place fresh bottle outside of cabinet.
4. Remove entire plastic cap from top of bottle.
5. Clean outside of new bottle with a cloth.
6. Place probe into bottle.
7. Slide collar down until it clicks in place.
8. Push head down until tubes hit bottom of bottle.
9. Slide bottle into cabinet and close door.
Provide Electricity
Plug cord into a properly grounded wall outlet. At this time the pump
will begin to move water from the bottle to the hot and cold tanks.
It will take up to 12 minutes to fill the tanks for the first time.
During this period the pump will run continuously. This is normal.
Activate Heating & Cooling
Notice: This unit will not dispense hot or cold water until the switches are activated.
To activate, push top side of power switches in to start heating and cooling water.
- If you do not want to heat water, push bottom side of red switch in.
- If you do not want to cool water, push bottom side of green switch in.
Activate Nightlight
Push top side of blue power switch in to turn light on. Push bottom side in to turn light off.
GETTING STARTED
English-4
5 Gallon Bottle
Head
Collar
3 Gallon Bottle
Head
Collar