Problem
The device does
not operate, the
compressor does
not start.
The compressor
operates, but the
refrigerator does
not chill.
The compressor
has been running
for a long time
but is not chilling
properly.
The compressor
operates
continuously.
3.4.

Cleaning and maintenance

a)
Before any cleaning, adjustment or replacement of accessories, and also when
the appliance is not in use, pull out the mains plug and cool the appliance
completely.
Wait for the rotating parts to stop.
b)
Only use only non-corrosive agents for cleaning the surfaces.
c)
Only gentle cleaning agents designed for cleaning food contact surfaces may
be used to clean the appliance.
d)
After each cleaning, all components should be thoroughly dried before the unit
is used again.
e)
Do not spray the device with a stream of water or immerse it in water.
f)
Ensure that no water enters through the ventilation openings in the casing.
g)
Clean the ventilation openings with a brush and compressed air.
Possible cause
No power or
incorrect power
connection.
Blown fuse of the
refrigerator.
Refrigerant
leakage through
the evaporator.
Improper air
circulation around
the unit, fan not
working properly,
drawer (door) not
closed.
Improper air
circulation around
the unit, high
ambient
temperature.
Solution
Check input voltage,
battery and power
connection.
Replace with an
operational fuse - its
socket is located on
the red wire of the
power supply
connection.
Check the unit for
leaks, refill the
refrigerant.
Improve air
circulation/ventilation
around the unit, check
the condition of the
fan, check the drawer
closure and its seal.
Improve ventilation
around the unit.