LIFT CORPORATION Sht. 1 of 10 DSG#
INSTRUCTION, IN CAB ON/OFF SWITCH
CABLE, 16-AWG
3-CONDUCTOR, 540" LG.
P/N 051076-14
QTY. 1
RING TERMINAL,
10-12 AWG
P/N 203253
QTY. 1
WARNING
!
To prevent accidental personal injury
and equipment damage, disconnect
(-) battery cable and (+) cable from
battery.
1. Disconnect power to the pump by
disconnecting negative (-) and positive
(+) cables from battery (FIG. 1-1). Re-
install nuts on negative (-) and positive
(+) battery terminals.
Estas instrucciones están disponibles en español a partir de la página 6.
© MAXON Lift Corp. 2017
KIT P/N 250477
DECAL
P/N 260941
QTY. 1
BUTT CONNECTOR,
14-16 AWG
P/N 030491
QTY. 2
NEGATIVE (-)
BATTERY CABLE
DISCONNECTING BATTERY POWER
M-88-38
Rev. B Date: 06/21/17
SWITCH, PUSH-PULL
P/N 250478
QTY. 1
RING TERMINAL,
14-16 AWG
P/N 203499-16
QTY. 2
POSITIVE (+)
BATTERY CABLE
NUT
NEGATIVE (-)
BATTERY POST
FIG. 1-1
POSITIVE (+)
BATTERY POST