Maxon 250477 Instrucciones página 5

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

LIFT CORPORATION Sht. 5 of 10 DSG#
Pump cover must be correctly secured to prevent it from becoming a
hazard. To secure pump cover, the long side of the holder flats must butt
against pump cover as shown in the illustration.
9. Bolt on the pump cover as shown in
FIG. 5-1. Hand tighten the threaded
cover knobs.
10. Reconnect power to the pump
by reconnecting positive (+)
cable to positive (+) battery
terminal (FIG. 5-2). Install and
tighten nut. Then, reconnect
negative (-) cable to negative
(-) battery terminal (FIG. 5-2).
Install and tighten nut.
11. Pull the knob out to turn the
switch ON (FIG. 5-3). Liftgate
should operate with control
switch. Push the knob in to
turn switch OFF. Liftgate
should not operate.
© MAXON Lift Corp. 2017
CAUTION
POSITIVE (+)
BATTERY POST
NUT
NEGATIVE (-)
BATTERY CABLE
RECONNECTED BATTERY CABLES
KNOB
M-88-38
Rev. B Date: 06/21/17
BOLTING ON PUMP COVER
FIG. 5-1
POSITIVE (+)
BATTERY CABLE
NEGATIVE (-)
BATTERY POST
FIG. 5-2
CONTROL KNOB
FIG. 5-3

Publicidad

Tabla de contenido
loading

Tabla de contenido