Maxon 250477 Instrucciones página 4

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

LIFT CORPORATION Sht. 4 of 10 DSG#
6.
Unbolt and remove pump cover
(FIG. 4-1).
7. Run the 3-conductor cable (Kit item)
through vehicle frame (FIG. 4-2).
Next, feed cable through rubber
grommet on pump mounting
plate (FIG. 4-2).
NOTE: The 3-conductor cable
contains a black wire.
Do not use the black
wire. Ensure cut end of
black wire is sealed and
taped to 3-conductor cable.
8. Splice the 3-conductor cable in line
with the GREEN control wire (FIG.
4-2).
© MAXON Lift Corp. 2017
UNBOLTING PUMP COVER
BUTT
CONNECTOR
WHITE WIRE
(NEW CABLE)
BUTT
CONNECTOR
GREEN WIRE
(NEW CABLE)
BLACK WIRE
(NEW CABLE)
NEW 3-CONDUCTOR
CABLE
PUMP MOUNTING PLATE
M-88-38
Rev. B Date: 06/21/17
FIG. 4-1
3-CONDUCTOR
LIFTGATE
PUMP WIRING CONNECTIONS
FIG. 4-2
GREEN CONTROL
WIRE
FUSE HOLDER
(REF)
CABLE
IN-CAB
SWITCH

Publicidad

Tabla de contenido
loading

Tabla de contenido