Technical Data - gefran GFX OP Manual De Uso

Terminal operador para la gamma geflex
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34
Main applications
• Plastic extruders
• Plastic injection presses
• Blowers
• Plastic and rubber processing
machines
• Wrapping machines
• Packaging machines
• Thermal processes with
electric heating
PROFILE
Terminal for configuration and diagnosis of
the whole Geflex series.
It is composed of a lexan membrane
(ensuring an IP65 front protection).
Three 4-digit displays, two of which to
display variables (PV process variable, SP
set point), and a 2-digit display to identify
Geflex queried node.
Six function keys to access the software
menus and make settings.
Fourteen LEDs: six for the output status
diagnosis, and eight for the status instru-
ment.
It comes with a built-in memory able to
save the complete configuration of each
Geflex, up to ten units.
This feature makes it particularly suitable
for plant maintenance, as Geflex units can
be configured directly on site and data
can then be stored on a PC.
Moreover, the opposite operation is also
available: download data from a PC to the
GFX_OP terminal, operate on the plant
and configure Geflex units.
Two versions are available:
back-of-board mounting: the terminal can
be installed directly on Geflex heat sink or
on a DIN rail;
front-of-board mounting: the terminal can
be fixed directly on the control board of
the plant.
GFX_OP
PROGRAMMING TERMINAL FOR GEFLEX RANGE
In both cases the terminal does not need
any external power supply, as this is provi-
ded directly by Geflexs.
A complete 24Vdc power supply and a
connection cable kit is provided for use
with a PC.
Can be used with GEFLEX
software release 1.3x
and previous releases
Main features
• Triple Display
• 6 function keys
• 14 LEDs
• Power supply 24Vdc
• Built-in memory to load/download Geflex

TECHNICAL DATA

F
4+4+2 digit display,
7 green segments, height 7 mm
14 red LEDs,
6 mechanical keys
Faceplate protection with lexan.
Installation
To faceplate panel.
Installed on DIN guide.
S
- RS485 interface for connection to the
GEFLEX modules.
- RS232 interface for connection with PC for
WINSTRUM software.
(see Geflex accessories)
P
24V ±25%, max. 80mA.
A 90...260Vac, 50...60Hz mains power sup-
ply is available as accessory.
It is not necessary when the terminal is con-
nected to an already powered GEFLEX
module.
A
Working temperature range: 0...50°C
Storage temperature range: -20...70°C
Humidity: 20...85% Ur non condensing
W
90g.
10
configuration up to 10 units
ACEPLATE
L
ERIAL
INE
S
OWER
UPPLY
W
MBIENT
ORKING
EIGHT