If the ICM is not functioning properly or is out of order, please check the following before calling the
authorized service provider:
FAULT
The ICM does not
work.
The cooler does
not cool.
The cooler does
not cool.
The ICM makes
noise.
There is water on
the floor.
The lights don't
work.
UNPLUG THE COOLER PRIOR TO ANY MAINTENANCE OR
SERVICE OPERATIONS. REMOVE THE PLUG AND MAKE SURE
THAT THE OPERATOR CAN CHECK FROM ANY OF THE POINTS
WHICH HE HAS ACCESS THAT THE CABLE IS UNPLUGGED.
After maintenance operations, make sure that the grounding
connections are in place before assembling the covers. Make sure
you use the same fastening components and covers.
If any electrical components need to be replaced, use only the
identical components in the spare part list supplied by the
technical service department of Frigoglass.
Keep the glass door of the cooler closed during cooling
mechanism maintenance. The appliance will not stand stable when
the compressor is disassembled. If the compressor needs to be
replaced, use adequate support to stabilize the cooler.
After maintenance operations make sure that the strain relief,
which supports the supply cord, is assembled properly.
POSSIBLE REASONS
Power cord not plugged in.
No power coming through the socket.
The ICM has recently been reloaded
with warm products. Please note that it
takes some time to cool warm
products.
The ICM is loaded in such a way that
the air circulation in the interior is
getting blocked.
The door does not seal properly.
Leakage in the cooling system.
Intense metallic noise.
Inclined or curved floor.
The drainage hole for the condensate
water is blocked.
There is a leakage in the tray.
The lighting or the transformer are out
of order.
HANDLING
Plug it in.
Check the outlet fuse.
Preferably, reload the ICM before night
closing.
Load the ICM according to the
standards you have been provided
with by the company.
Repair the doors for proper closing
(this type of repair should be
performed by an authorized
technician).
Repair the leakage (this type of repair
should be performed by an authorized
technician).
Call a Service technician.
Level the ICM properly by adjusting its
feet. Placing a spirit level on the top of
the ICM will assist you in leveling it.
Unblock the drainage hole.
Call a Service technician.
Call a Service technician.
ENG
12