Transponder reader function
- Move a master tag / card near to the remote transponder reader.
- Every 3 seconds the software will cycle through the channels that can be associated with the new tag/card accompanied by the sounding of the
buzzer as follows:
3 sec
- Once you have chosen the channel remove the master tag / card from the reader. Within 10 seconds bring the tag/card to be memorised near to
the reader. The reader will sound a beep to confirm. The code was accepted and the functions assigned.
5. Cancelling user codes locally
Interface
- Move jumper J2 on the interface to 'pos. 1' then press button P2 and hold down for at least 2 seconds.
- The buzzer B1 will sound 'beep' to confirm and during the procedure the red led L1 will flash quickly.
- The user code cancellation procedure will be activated with a time out maximum of 30 seconds.
Keypad function
- Type the code to be cancelled into the keypad and press " ". The interface will sound a beep to confirm. The code has been cancelled.
Transponder reader function
- Move the tag / card you want to cancel near to the transponder reader. The interface will sound a beep to confirm. The code has been cancelled
If you have inserted an invalid code or used a tag that has not been memorised the interface will sound 5 consecutive beeps and if the
memory content is empty the interface will sound 10 beeps.
6. Cancelling user codes remotely
Keypad function
- Type into the keypad the sequence: "# 'code to cancel' #".
- The keypad will sound a two-second long beep with the red and green leds lit. The code has been cancelled.
Transponder reader function
- Move a master tag close to the transponder reader and hold it there until the reader sounds 5 beeps.
- Remove the master tag from the reader. Within 10 seconds bring the tag to be cancelled near to the reader.
- The reader will sound a beep to confirm.
3 sec
3 sec
CHA
CHB
1 bip
2 bip
(this procedure it is possible to cancel a keypad / transponder reader user code).
(using this procedure you may cancel a keypad, tag or card user without directly accessing the interface).
3 sec
CHC
CHD
3 bip
4 bip
25
3 sec
DEL
5 bip
Attention!
Cancellation will only be
possible if jumper "J2" is in
position 1.