1. Connecting to an access control device
2. Choosing the output protocol
3. Selecting the output voltage
4. Timer controlled operation
5. WIEGAND protocol (bit flow sequence)
6. ISO2 protocol (bit flow sequence)
7. SERIAL protocol (bit flow sequence)
8. Code truncation
9. Setting up additional functions
Attention: Multiprotocol interface standard operation is enabled
by moving J3 to position 1.
1. Connecting to an access control device
WIEGAND or SERIAL protocol:
The physical connection between the access
control device and the RCQ504/508W00 interface
is carried out at the following binding posts:
9 (DO), 8 (DI) and 6 (GND).
ISO2 protocol (magnetic stripe)
The physical connection between the access
control device and the RCQ504/508W00 is
carried out at the following binding posts:
9 (RCP, "read clock pulse"), 8 (RDP, "read data
pulse"), 7 (CLS, "card loading signal") and 6 (GND).
MULTIPROTOCOL INTERFACE STANDARD OPERATION
5
6
7
8
9
GND
DI
5
6
7
8
9
GND
CLS
RDP
2. Choosing the output protocol
The interface has 16 different
formats for communicating with
the access control device. 11 of
these formats are WIEGAND, one
is ISO2, one is SERIAL and 3 are
CARDIN formats. They can be
selected using the dip-switch "S1".
To select the output protocol
proceed as follows:
- switch off the interface;
- set the dips following the table;
- press and hold down P1;
- switch on the interface which will sound one long beep.
The protocol has been set. For a detailed description of the bit transmission
sequence consult paragraphs 4 - 5 - 6 and 7.
DO
3. Selecting the output voltage
There are three different methods for choosing the output voltage for the
formats WIEGAND, ISO2 and SERIAL:
1) 12 Vdc output with jumper "J4" in position "1".
2) 5 Vdc output with jumper "J4" in position "2".
3) TTL Open collector output with jumper "J4"
RCP
in position "3" (open contact).
28
DIP1 DIP2
DIP3
DIP4
PROTOCOL
ON
OFF
OFF
OFF
WIEGAND 26 BIT
ON
OFF
ON
OFF
WIEGAND 26 BIT SITE
ON
OFF
ON
ON
WIEGAND 26 BIT SITE + CH
OFF ON
OFF
OFF
WIEGAND 37 BIT
OFF ON
OFF
ON
WIEGAND 37 BIT + CH
OFF ON
ON
OFF
WIEGAND 37 BIT SITE
OFF ON
ON
ON
WIEGAND 37 BIT SITE + CH
OFF OFF
ON
OFF
WIEGAND 37 BIT D10302
OFF OFF
ON
ON
WIEGAND 37 BIT D10302 (BCD)
ON
ON
OFF
OFF
WIEGAND 50 BIT
ON
ON
OFF
ON
WIEGAND 50 BIT + CH
OFF OFF
OFF
ON
ISO 2
ON
ON
ON
ON
SERIAL
ON
ON
ON
OFF
CARDIN EXPANSION
Pos.1
Pos.1
Pos.1
Pos.2
Pos.2
Pos.3
Pos.3
Pos
Pos.3