Caution: Having turned on the appliance for the first time, it is recommended to
trigger the sensor several times (using a hand, for example). This will vent air from
the dispenser pump. Repeat this until the nozzle releases the liquid hand soap when
the sensor is triggered.

3.5. Operating the appliance

Setting the sensor detection range
1)
Press and hold the power switch [I].
2)
When the blue indicator light comes up, place an object (a hand) at the
distance you wish it to be detected.
3)
The blue indicator light will go off and the sensor detection range is set.
Liquid soap dose setting
1)
Press the liquid soap dose control button [L] once and the indicator light in the
sensor window will flash once with a single beep, indicating that the dispensed
dose volume setting is "1".
2)
Press the liquid soap dose control button [L] twice and the indicator light in the
sensor window will flash twice with two beeps, indicating that the dispensed
dose volume setting is "2".
3)
Press the liquid soap dose control button [L] three times and the indicator light
in the sensor window will flash three times with three beeps, indicating that
the dispensed dose volume setting is "3".
4)
Now, pressing the liquid soap dose control button [L] again will revert the
setting to "1".
HINT: The appliance will store the last setting of the dose volume. If the power to
the appliance is lost and reconnected, the last setting will not change.
Other information
a)
Make sure that the liquid soap is clean and not contaminated by any solids or
deposits. A liquid soap too greasy or sticky may clog the pump. To prevent this,
you can dilute the soap with some water. If the soap thinned with water still
cannot be pumped out by the dispenser, change the soap to a different liquid
product.
b)
When brand-new or filled with a fresh batch of liquid hand soap, the soap
dispenser may require repeated attempts at triggering the sensor before the
first dose of soap is dispensed, as the pump may need to vent air.
c)
If the soap dispenser is refilled and left unused for a long time, it is best to drain
the liquid hand soap and refill the dispenser with water. Next, remove all water
by triggering the soap dispenser to dispense. Otherwise, the liquid soap left in