Specifications
Modèle
CV
Hz
Volts/Ph
SWF300M2-20
3
60
230/1
SWF300M3-20
3
60
230/3
SWF300M4-20
3
60
460/3
SWF300M5-20
3
60
208/1
SWF300M6-20
3
60
208/3
SWFD300M2-20
3
60
230/1
SWFD300M3-20
3
60
230/3
SWFD300M4-20
3
60
460/3
SWFD300M5-20
3
60
208/1
SWFD300M6-20
3
60
208/3
SWF500M2-20
5
60
230/1
SWF500M3-20
5
60
230/3
SWF500M4-20
5
60
460/3
SWF500M5-20
5
60
208/1
SWF500M6-20
5
60
208/3
SWFD500M2-20
5
60
230/1
SWFD500M3-20
5
60
230/3
SWFD500M4-20
5
60
460/3
SWFD500M5-20
5
60
208/1
SWFD500M6-20
5
60
208/3
Note: All dimensions have a tolerance of + 1/8"
SWH300/500
Série SWF300/SWF500
Pompes d'égouts
Modèles: SWF300/SWF500 & SWFD300/SWFD500
Spécifications
T/MIN
Amp Pleine
Typee de
Code démarrage
charge
NEMA
cordon
1750
28.0
D
SOW
1750
20.0
D
SOW
1750
10.0
D
SOW
1750
33.5
D
SOW
1750
18.0
D
SOW
1750
28.0
D
SOW
1750
20.0
D
SOW
1750
10.0
D
SOW
1750
33.5
D
SOW
1750
18.0
D
SOW
1750
45.6
D
SOW
1750
23.6
D
SOW
1750
11.8
D
SOW
1750
46.0
D
SOW
1750
24.0
D
SOW
1750
45.6
D
SOW
1750
23.6
D
SOW
1750
11.8
D
SOW
1750
46.0
D
SOW
1750
24.0
D
SOW
Taille de
Cordon
Relais
cordon
O.D.
potentiel
Continuous Coil Min Voltage:350V
8AWG/4C
1.0
Pickup Max:200V Drop Out Max:75V
12AWG/4C
.7
N/A
12AWG/4C
.7
N/A
Continuous Coil Min Voltage:350V
8AWG/4C
1.0
Pickup Max:200V Drop Out Max:75V
12AWG/4C
.7
N/A
Continuous Coil Min Voltage:350V
8AWG/4C
1.0
Pickup Max:200V Drop Out Max:75V
12AWG/4C
.7
N/A
12AWG/4C
.7
N/A
Continuous Coil Min Voltage:350V
8AWG/4C
1.0
Pickup Max:200V Drop Out Max:75V
12AWG/4C
.7
N/A
Continuous Coil Min Voltage:400V
6AWG/4C
1.2
Pickup Max:200V Drop Out Max:80V
12AWG/4C
.7
N/A
12AWG/4C
.7
N/A
Continuous Coil Min Voltage:400V
6AWG/4C
1.2
Pickup Max:200V Drop Out Max:80V
12AWG/4C
.7
N/A
Continuous Coil Min Voltage:400V
6AWG/4C
1.2
Pickup Max:200V Drop Out Max:80V
12AWG/4C
.7
N/A
12AWG/4C
.7
N/A
Continuous Coil Min Voltage:400V
6AWG/4C
1.2
Pickup Max:200V Drop Out Max:80V
12AWG/4C
.7
N/A
SWFD300/500
Série SWFD300/SWFD500
31
Condensateur
de démarrage
Condensateur de course
750uf+/-5%-220VAC
40uf+/-5%-370VAC
N/A
N/A
N/A
N/A
750uf+/-5%-220VAC
40uf+/-5%-370VAC
N/A
N/A
750uf+/-5%-220VAC
40uf+/-5%-370VAC
N/A
N/A
N/A
N/A
750uf+/-5%-220VAC
40uf+/-5%-370VAC
N/A
N/A
750uf+/-5%-220VAC
40uf+/-5%-370VAC
N/A
N/A
N/A
N/A
750uf+/-5%-220VAC
40uf+/-5%-370VAC
N/A
N/A
750uf+/-5%-220VAC
40uf+/-5%-370VAC
N/A
N/A
N/A
N/A
750uf+/-5%-220VAC
40uf+/-5%-370VAC
N/A
N/A