Maintenance; Technical Data - Vetus PFWS Manual De Instalación Y Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 12
5

Maintenance

Cleaning the Water Filter
• Unscrew and remove the cover (drawing 6).
• Clean the filter element thus exposed.
• Refit the cover.
Checking and Adjusting the Pressure Switch (drawing 7)
Switch on pressure:
• Open a tap a quarter of a turn only. As the water runs out slowly
the pressure will reduce. Now watch the manometer for the pres-
sure at which the pump is switched on.
Increase switch-on pressure : Turn nut 2 to the right.
Decrease switch-on pressure : Turn nut 2 to the left.
Switch-off pressure:
• Leave the tap open quarter of a turn, so that the water pressure in
the tank increases slowly. Now watch the manometer to read the
pressure at which the pump is switched off.
Increase switch-off pressure: Turn nut 1 to the right.
Decrease switch-off pressure: Turn nut 1 to the left.
6

Technical data

Type
Electric motor, type
Voltage
Current at 0.7 Bar (10 psi)
Pump, type
Capacity at 2 Bar (30 psi)
Max. pressure
Maximum riser height
Filter, type
Mesh size
Pressure switch
Settings,
Switch-on pressure
Switch-off pressure
Range,
Min. switch-on pressure
Max. switch-off pressure
Manometer
Meter range
Pressure tank
Capacity
Pre-pressure, air cushion
Connections,
Hose
Water temperature
Weight
Pressurized-water system PFWS
:
PFWS1219
:
:
12 V DC
:
15 Amp
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
N.B. Nut 1 adjusts the difference between switch-on and switch-off
pressure. After resetting the switch-on pressure, the switch-off pres-
sure must also be adjusted again.
Checking and pressurizing Pre-pressure and Air Cushion
• Remove the protective cap, turn
to the left and check pressure
with a tyre air pressure meter.
Reduce pressure: Push the Schrä-
der valve pin in; air will now es-
cape.
Increase pressure: Connect a car
tyre pump to the valve and bring
the air cushion to the required pressure.
Replacing the Membrane
Under normal circumstances the membrane should never need
replacement. However if it does leak, replace as follows:
- Ensure that the whole system is de-pressurized.
• Remove the hose between pump and T-piece, remove the 6 bolts
holding the flange to the top of the tank and remove flange com-
plete with T-piece.
• Remove the old membrane, refit a new one and reassemble in
reverse order to the above.
Permanent magnet DC motor
Self-priming 5 valve diaphragm pump
20 litres/min (4.4 Imp.Gallon)
4.2 Bar (61 psi)
1.8 m (6 ft)
In-line
50 Mesh
1.4 Bar (20 psi)
2.8 Bar (40.6 psi)
1 Bar (14.5 psi)
5 Bar (72.5 psi)
0 to 6 Bar (0 - 87 psi)
19 litres (4.2 Imp.Gallon)
1.2 Bar (17.4 psi)
19 mm (3/4")
0 to 50 degrees C. (32 to 122 degrees F.)
9.5 kg (20.9 lb)
ENGLISH
PFWS2419
24 V DC
8 Amp
050408.01
7

Publicidad

Tabla de contenido
loading

Tabla de contenido