DEVICE CONTROL. Z-WAVE APPLICATION COMMAND CLASS MAP-
PING
The Aidoo Z-Wave Plus controller acts as a gateway between the air conditioner controller
interface and the Z-Wave network. The Aidoo Z-Wave Plus interacts with the proprietary
protocol of the different A/C manufacturers converting the orders into Modbus commands to
trigger the Z-Wave network commands.
The monitoring/control items supported by the Aidoo Z-Wave Plus are mapped to the standard
Thermostat Command class object types defined by the Z-Wave protocol. The user can interact
with the air conditioning system through the Z-Wave network with the following supported
monitoring/control items.
Description
On/Off
SetPoint
LocalTemp
Modes
Speed
Warning
Error
(*) For the Notification Z-Wave command class, the Aidoo Z-Wave Plus reserves 2
alphanumeric bytes to represent the Air conditioning unit warnings and error codes. The
warnings and error codes are represented in a different way according to each manufacturer.
Please refer to the manufacturer's installation manual to check the meaning of the different
codes.
12
N° of max nodes
supported in the
Description
group
Life Line
1
Group
Values
Off
On
- SetpointType: (Heating,
Cooling, Dry Air)
- SetPointValue: (tenths of °C)
Room temperature x10
OFF
Auto chageover
Cooling
Heating
Fan
Dry
Auto - Medium
Low
Medium
High
Off
Max 2 Byte
Max 2 Byte
Command sent
DEVICE_RESET_LOCALLY_NOTIFICATION
THERMOSTAT_FAN_MODE_REPORT
INDICATOR_REPORT
THERMOSTAT_MODE_REPORT
THERMOSTAT_SETPOINT_REPORT
SENSOR_MULTILEVEL_REPORT
NOTIFICATION_REPORT
Z-Wave Command
Thermostat_Mode
Thermostat_Mode
Thermostat_Setpoint
Sensor_Multilevel
Thermostat_Mode
Thermostat_Fan_Mode
Notification(*)