6 - PROTECTION FUSES
Position
Value
F1
5 A
7 -
FUNCTIONS PROGRAMMING
The settings are memorized during the pause phase (door closed).
The DEFAULT settings are highlighted in grey.
Function
DIP
Status
OFF
TERMINALS 6-7
DIP 1
OPERATION
ON
OFF
AUTOMATIC
DIP 2
RECLOSING
ON
OFF
TIMES
DIP 3
LEARNING
ON
STEP - STEP
DIP 4
OFF
WITH STOP
Description
Type
Board protection on 230 Vac power supply input
FAST
(DIP SWITCH - DIP1)
Description
The outputs 6-7 of the terminal board are used to manage a FLASHING LIGHT.
Slow flashing in opening and fast in closing, off in pause and at rest.
The outputs 6-7 of the terminal board are used to manage a COURTESY LIGHT,
stays active for 2 minutes after the movement of the motor.
Automatic closing disabled.
Automatic closing enabled.
Function enabled only if the manoeuvre happens after a START command.
Standard operation.
Time learning enabled.
Operation of transmitters with one button:
Repy to START command:
• Shutter closed
• During opening
• Shutter open
• During closing
• After a Stop
NOTE: If the automatic closing is enabled, after the end of the opening and passed
the pause time, the control unit automatically closes. Function enabled only with
operation with one button.
Operation of transmitters with two buttons:
Repy to OPEN command:
• Shutter closed
• During opening
• Shutter open
• During closing
• After a Stop
THE CONTROL UNIT IS COMPATIBLE ONLY WITH
THE TRANSMITTERS OF MAKO 868MHz SERIES.
OPENS
STOPS
CLOSES
STOPS
movement opposed to the one before STOP
Repy to CLOSE command:
OPENS
• Shutter closed
STOPS
• During opening
IRRELEVANT
• Shutter open
STOPS
• During closing
OPENS
• After a Stop
SR302
IRRELEVANT
STOPS
CLOSES
STOPS
CLOSES