Warnings For The User - GiBiDi SR302 Instrucciones Para La Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SR302
• Before carrying out any cleaning or maintenance operation, disconnect the control unit from the mains.
• This control unit may only be used for the purpose for which it was designed.
• The use of the products for purposes different from the intended use has not been tested by the manufacturer,
therefore any work is carried out on full responsibility of the installer.
• Mark the automated gate with visible warning plates.
• Warm the user that children or animals have not to play or stand near the gate.
• Appropriately protect the dangerous points (for example, use a sensitive edge).

4 - WARNINGS FOR THE USER

In the event of an operating fault or failure, cut the power upstream of the control unit and call Technical Service.
Periodically check functioning of the safety devices. Any repairs must be carried out by specialised personnel using
original and certified materials.
The product is not to be used by children or people with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision or instruction. Do not intervene on the board for
regulations and/or maintenance.
5 - ELECTRICAL CONNECTIONS: TERMINAL BOARDS
Terminal
Position
1
2
3
OUT MOTOR CLOSE
J1
4
OUT MOTOR COM
5
OUT MOTOR OPEN
6
7
8
9
10
11
J2
12
13
14
WARNING: IMPORTANT SAFETY INSTRUCTION
For people's safety, it is important to follow this instruction.
Please keep this manual.
Signal
Description
230 Vac line input (Phase)
IN 230Vac
230 Vac line input (Neutral)
Motor connection (closing)
Motor connection (common)
Motor connection (opening)
OUT LAMP
Courtesy light / flashing light 230Vac output
OUT LAMP
Courtesy light / flashing light 230Vac output
Accessories power supply output
OUT 12Vac
Accessories power supply output
IN EDGE
Edge input (N.C.) if DIP6 OFF; Stop Input (N.C.) if DIP6 ON
Photocell Input (N.C.) enabled only in closing.
With operation logic:
STEP BY STEP WITH STOP
IN PHOTO
DEAD MAN IN CLOSING
DEAD MAN IN OPENING AND CLOSING
COM
Common for Edge, Photocell, Start, Close and Open inputs.
BUTTON DOWN
CLOSE command input (N.O.) see DIP8.
START command input (N.O.) if DIP 8 in ON.
BUTTON UP
OPEN command input (N.O.) if DIP 8 in OFF. See DIP8
UK
REVERSES THE MOTION
REVERSES THE MOTION
STOPS THE MOTION
13
IT

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

As07300

Tabla de contenido