Installation
STEP 4 Connect the water hose
The dryer must be connected to a cold water tap using the provided water hoses.
If the Y-connector cannot be directly connected to the cold water tap, use the short hose. See the "Using
the short hose as an extension" section on page 25.
24
English
Untitled-14 24
1. Close the cold water tap. If you have a washer's cold
water hose attached to the cold water tap, unscrew
and remove the hose. Then, connect the female end
of the Y-connector to the cold water tap.
2. Connect the straight end of the water hose to the
Y-connector.
3. Using pliers, tighten the coupling an additional two-
thirds turn. Do not overtighten because the coupling
may be damaged.
4. Connect the angled end of the water hose to the
filling valve at the bottom of the rear frame. Turn the
coupling manually until it is tight.
5. Using pliers, tighten the coupling an additional two-
thirds turn. Do not overtighten because the coupling
may be damaged.
6. If you detached the cold water hose from your
washer, attach the hose to the open end of the
Y-connector, tighten the coupling by hand until it is
tight, and then, using a pliers, tighten an additional
two-thirds turn.
7. Open the cold water tap, and then check for any
leaks.