Technical Data; Mechanical Installation - jcm-tech RCONTACT R Manual De Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

RCONTACT R
User's Manual
Introduction
The system is designed for applications where pedestrian doors installed on garage doors. Is a position detection system of
the pedestrian door status, so that if it is open the system prevents the start of the movement of the garage door.
Is a wireless system composed by one transmitter and one receiver. The receiver monitors the status of transmitters connected to it.
The system complies with EN ISO 13849-1, category 2, PLc.

Technical data

Frequency
Power supply
Consumption standby/operating
Memory
Relay numbers
Relay contacts
Radiated power
Operating temperature
Seal
Box size
Range
Starting up

Mechanical installation

Fix the back of the box to the wall, using the wall plugs and screws supplied. Install the receiver, close to the door and avoid metal
surfaces between the receiver and the transmitter. Pass the cables through the bottom of the receiver. Connect the power cables to
the terminals of the printed circuit, following the indications of the connections diagram. Store the transmitter on the receiver. Fix
the front of the receiver to the back with the screws supplied for the purpose.
Programming the transmitter on the receiver
While programming the receiver, press the PROG button on the transmitter to be programmed into the receiver.
The receiver allows programming 6 transmitters (3 for Relay 1 and 3 for Relay 2).
Each safety edge transmitter must be learnt into the appropriate channel of the safety edge receiver.
3200369_RCONTACT-R_EN_Rev03
869,50 MHz
12/24V ac/dc (9-35V dc / 8-28V ac)
18mA/80mA
6 transmitters (3 on relay 1, 3 on relay 2)
2 relays
1A
< 1mW
-20ºC - +85ºC
IP54 (with IP65 cable glands)
82 x 190 x 40mm
50m
Page 1/3

Publicidad

Tabla de contenido
loading