CORRECT OPERATION OF THE SYSTEM
If no other acoustic signal is heard on completing the manoeuvre, the system is operating correctly. Either press the CHECK
button again or wait 5 minutes and the receiver will exit checking automatically, indicating with two beeps that the check
has been correct. The check indicator light will go out.
DETECTION OF TRANSMISSION FAILURE
If the communication with a transmitter fails during checking, or the communication is deficient (for instance, too many
communication retries or poor coverage), the receiver emits three consecutive beeps, indicating that an error has occurred.
Halt the door manoeuvre and open the pedestrian door to detect what has failed.
If a single beep is heard on opening the pedestrian door, this means that the safety edge is correct.
-
If three consecutive beeps are heard on opening the pedestrian door, this means that the safety edge has failed.
-
In this event, it is recommended changing the orientation of the transmitting-receiving aerials or installing an AED-
868 or FLAT-868 outdoor aerial to ensure the desired range.
On exiting check mode, seven consecutive beeps will be heard and the indicator light will flash continuously.
Perform another system check until the result is correct.
Signal coverage
After opening the pedestrian door, continuous flashes, ranging from 1 to 5, indicate the signal coverage for the transmitter
at the time it was detected.
Number of check LED flashes
1
2
3
4
5
Total reset
In programming mode, keep the programming PROG button pressed down and make a bridge with the "MR" reset jumper for 3s.
The receiver will emit 10 warning sound signals and then more at a faster frequency, indicating that the operation has been carried
out. The receiver will stay in programming mode.
If 10 seconds pass without programming a transmitter, the receiver will exit the programming mode, emitting two 1 sec beeps.
Replacing a transmitter
If a transmitter becomes damaged the whole system must be reset and replaced, and non-damaged transmitters must then be re-
programmed into the receiver.
Use of the system
This equipment is designed for applications where pedestrian doors installed on garage doors. It is not guaranteed for
directly activating equipment other than that specified.
The manufacturer reserves the right to change the specification of the equipment without prior warning.
Important annex
Disconnect the power supply whenever you proceed to the installation or repair of the control panel.
In accordance with the European low voltage directive, you are informed of the following requirements:
-
For permanently connected equipment, an easily accessible connection device must be incorporated into the cabling.
-
This system must only be installed by a qualified person that has experience with automatic doors/gates and knowledge of the
relevant EU standards.
-
The instructions for use of this equipment must always remain in the possession of the user.
-
The frequency of the RContact system does not interfere in any way with the 868 MHz remote control systems.
JCM TECHNOLOGIES, S.A. declares herewith that the product RCONTACT R
requirements of the RED Directive 2014/53/EU, as well as with the Machine Directive 2006/42/EC whenever its usage
is foreseen; and with the 2011/65/EU RoHS Directive.

EC Declaration of conformity

See web www.jcm-tech.com
JCM TECHNOLOGIES, SA · C/COSTA D'EN PARATGE 6 - 08500 VIC (BARCELONA) SPAIN
3200369_RCONTACT-R_EN_Rev03
Coverage
Result of check
Very weak
Safety edge failure
Weak
Normal
Good
Very good
OK
OK
OK
OK
complies with the relevant fundamental