Filling the pump with water (Fig. A, H)
1. Unscrew and remove the filling plug (5).
2. Fill the pump with clean tap water, as shown on
figure H. Do not overfill the pump.
3. Place the filling plug (5) back, do not overtighten.
4. OPERATION
Never use this pump in a pond or swimming
pool while people are present in the water!
Only switch the power on or off with dry
hands.
Never run this pump before the pump and
the suction hose (8) is filled with water.
Clean the foot valve (not included) and
pre-filter (not included) at regular intervals,
and check it for damage. Otherwise, its
function can be impaired.
Switching on/off (Fig. A)
1. Check that the ON/OFF switch (1) of the pump
is in the 'O' position before connecting the
pressure switch to the power supply.
2. Move the ON/OFF switch (1) of the pump into
the position 'I' to switch the pump on.
3. With the pressure switch you can automatically
control the operation of a garden pump. Open
the connected tap or spray gun to start the
pump. When you start the pump, there will be
a lot of air in the water first. This is not a defect
of your pump, but serves to remove air from the
pump. It may take several minutes for the air to
escape when the pump is used for the first time.
4. When you close the connected tap or the spray
gun, the pump automatically stops pumping.
5. Move the ON/OFF switch (1) of the pump into
the position 'O' to switch the pump off.
WWW.VONROC.COM
The pressure switch has 3 LED indicators (13, 14,
15) which indicate the status of the pressure switch:
LED indicators Operating status
The pressure switch is connected to
LED-power (13)
the power supply. The pressure switch
is ready for use.
The pump is running dry without water.
The dry-run safety is activated. Use the
pump's operating manual to find the
LED-failure (14)
cause of the failure and correct it. Then
restart the pump by pressing the reset
button (12) on the pressure switch.
LED-on (15)
The pump is operating.
Reading the pressure (Fig. B)
The pipe pressure can be read on the pressure
gauge (11). The black scale indicates the pressure
in bar.
Setting the switch-on pressure (Fig. A, B)
The default switch-on pressure is 1.5 bar. The
switch-on pressure can be adjusted to a value
between 1.5 bar to 2.5 bar.
It is possible to set the switch-on pressure by using
the pressure setting screw (16). Every 360° turn
decreases or increases the switch-on pressure for
approx. 0.2 bar.
• By turning clockwise, the pressure will be
increased.
• By turning anti-clockwise, the pressure will be
decreased.
Finish operation (Fig. A, I)
Do not touch the pump unless its power has
been cut off for at least 5 minutes.
When there is the risk of frost or if you do
not use your pump for a long time, please
properly store your pump.
1. Check that the ON/OFF switch (1) is in the 'O'
position.
2. Remove the mains plug from the mains.
3. Unscrew and remove the drain plug (2). Let the
water drain.
4. Pull up the suction hose (be aware, it is full of
water).
5. Unscrew the suction hose (8) from the water
EN