EN
Clogged dust collection bag (17) can burst.
-therefore make sure to replace the dust
collection bag in a timely manner!
1. Switch off (1) the machine and remove the
battery.
2. Unlock the locking clamp (6) and remove the
top section (7).
3. Before vacuuming, remove all dirt and debris
from the container (8).
4. Carefully slide HEPA filter (14) down over the
filter cage (15) making sure the whole cage is
covered as shown in Fig. F1.
5. For vacuuming with dust collection bag (17):
• Hold the cardboard collar tightly and slide
the rubber protective element as far as
possible onto the intake port (11) as shown
in Fig. G.
• When everything is in place, unfold the
bag (17) out and position it around the
inside walls of the container (8).
6. Reattach the top section (7) again and lock the
locking clamp (6).
7. Insert one end of the hose (12) into the va-
cuuming port (10). Fully unwind the suction
hose (12).
For vacuuming:
8. Insert the battery.
9. Press the power switch (1) into the "ON/I" posi-
tion to start your vacuum cleaner.
10. The machine now is ready to use for dry vacuum
cleaning.
11. Press the power switch (1) into the "OFF/0"
position to switch off your vacuum cleaner.
For working with power tools:
8. Adapt the power tool adapter (21) to the dust
extraction outlet of the power tool. Using a knife
if necessary.
9. Connect the power tool adapter (21) to the
hose (12) and connect it to the power tool dust
extraction outlet.
11. Insert the battery.
12. Press the power switch (1) into the "ON/I" posi-
tion to start your vacuum cleaner.
13. The machine now is ready to use for dry vacuum
cleaning.
14. Press the power switch (1) into the "OFF/0"
position to switch off your vacuum cleaner.
10
Wet vacuuming (Fig. F2)
The vacuum cleaner is equipped with a
float (16). The suction power decreases
when the maximum filling level is reached.
Switch the vacuum cleaner off (1)
immediately. Empty the container (8).
Clean the float (16) at regular intervals, and
check it for damage. Otherwise, its function
can be impaired.
Never reach into the water to be suctioned
up. Danger of electric shock.
Immediately switch (1) the machine off if
foam forms or liquids escape!
Do not use a dust collection bag (17)!
1. Press the power switch (1) into the "OFF/0"
position and remove the battery.
2. Unlock the locking clamp (6) and remove the
top section (7).
3. Before wet vacuuming, remove the dust collec-
tion bag (17), the HEPA filter (14) and remove
all dirt and debris from the container (8).
4. Carefully slide foam filter (13) down over the
filter cage (15) making sure the whole cage is
covered as shown in Fig. F2.
5. Reattach the top section (7) again and lock the
locking clamp (6).
6. Insert one end of the hose (12) into the va-
cuuming port (10). Fully unwind the suction
hose (12).
7. Insert the battery.
8. Press the power switch (1) into the "ON/I" posi-
tion to start your vacuum cleaner.
9. The machine now is ready for wet vacuum
cleaning.
10. Press the power switch (1) into the "OFF/0"
position to switch off your vacuum cleaner.
11. Raise the hose (12) so that the liquids drains
into the container (8).
12. Empty the container (8) immediately after sucti-
on cleaning because it is not designed to store
liquids.
Blow function (Fig. D2)
Operation without the use of a filter is
recommended.
WWW.VONROC.COM