BOMANN TCL 6045 QC CB Manual De Instrucciones página 92

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 53
The minimum distances (in mm) are marked in the illustration.
CAUTION:
• The purchaser must ensure that persons / firms / companies which
install, maintain or repair these air conditioning units possess
sufficient qualifications and experience working with refrigerating
agents.
• Improper installation and operation without verification (e. g. certifi-
cate) from a specialist company shall cause the warranty to expire
in accordance with (EU) 517 / 2014 Chapter II Art. 3.
Installing the Wall Mount
CAUTION:
Before you install the wall mount, make sure you have found the
precise spot at which you are going to drill the hole for the pipes! See
the chapter entitled "Installation of the Interior Unit and Wall Bushing
to the Outside".
1. Loosen the wall mount at the locking clips.
2. Fold the wall mount upward.
92
CL6045QCCB_IM
3. Remove the wall mount by releasing it from the holder.
4. Drill holes at least 32 mm deep in a solid wall in order to fasten the
plate.
5. Place the plastic dowels in the hole.
6. Fasten the mounting plate to the wall using the screws included.
7. Ensure that the mounting plate is screwed firmly in place.
Alignment of the Cooling Pipes
CAUTION:
The air conditioning unit must be installed and connected by a certi-
fied refrigeration and air conditioning company. Improper installation
shall result in expiry of the warranty.
The cooling pipes can be laid in 3 directions as depicted in accordance
with the numbers in the illustration. If the piping is placed in accordance
with options 1 or 3, then you must use a cutter to carefully cut a notch in
the side of the interior unit along the seam.
Guide the connection pipes in the direction of the opening in the wall
and bind the cooling pipes, the condensed water piping and the power
cable together using vinyl tape and always ensure impermeable insu-
lation so that no liquids, water vapour or condensate are permitted to
form and e. g. penetrate the wall. This will prevent the accumulation of
moisture as well as the formation of mildew. Ensure that the condensed
water pipe is placed on a gentle incline so that the water flow is not
obstructed.
CAUTION:
Ensure that the pipes are impermeably sealed to avoid moisture dam-
age and mildew build-up in the walling.
17.12.20

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cl 6046 qc cbCl 6047 qc cb

Tabla de contenido