3
Operation
Use Instructions
1. Remove all packaging from the components.
2. Pull the green pressure release valve (a) until the red
portion of the stem is showing to confirm the unit is
not pressurized.
3. With the pump handle (b) pressed fully down, hold
the unit and unscrew the pump assembly from the
tank head (c) to access the filler hole (d).
4. Follow all instructions from the chemical
manufacturer when filling the unit. Fill the tank (e)
¾ full with pre-mixed solution. Do not overfill
the tank.
5. With the pump handle (b) pressed fully down, hold
the unit and screw the pump assembly back into the
tank head to close the unit.
6. To pressurize the tank, rotate the handle of the pump
assembly until it is free then pump up the unit.
The pressure relief valve (a) will begin leaking air
when the tank is fully pressurized.
7. Once the desired pressure has been achieved,
push the pump handle (b) down and rotate to lock
it in place.
8. To start foaming, point the wand (f) on the trigger
gun towards the area you wish to foam and
squeeze the trigger handle (g) to discharge foam.
After Use Instructions
1. Release air pressure from unit after each use by
activating the pressure relief valve (a).
2. Empty out remaining solution and run fresh water
through the unit to rinse all parts thoroughly after
each use and before storage.
Model:
F5.0L-CE
|
F5.0L-PSG-CE
8
f
g
5
2
a
F5.0L-PSG-CE
User Manual
Original Instructions
3
b
4
c
e
V20221012
•
Page 6 of 52