That the machine is clean and dry.
That all assembly parts and fixing elements are firmly fixed, respectively tight.
The recommended hose size is from 12 mm to 16 mm for the inner diameter and between
15 and 30 m for the length. Always connect the return hose first and disconnect it at last (see
fig. 2).
When connecting the machine, pay attention that the valve trigger 1 (see fig. 3) is not
actuated.
Never connect any hydraulic hose under pressure (see safety instructions for prevention of
hazards caused by hydraulic).
32
P (Pump connection) = Supply
T (Tank connection) = Return flow
OUT (T)
Fig. 2
STARTUP
Fig. 3
IN (P)