Hama 00186421 Instrucciones De Uso página 7

Ocultar thumbs Ver también para 00186421:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 25
6.3 Basic setting and manual settings
Automatic setting according to the DCF signal
• After successful transmission of the indoor and outdoor
temperatures between the measuring and base stations, the
weather station (after around 3 minutes) automatically starts
searching for a DCF signal. The DCF radio symbol
during the search process.
• When the radio signal is received, the date and time are
set automatically. This can take a further 10 minutes. After
successful reception, the DCF symbol changes from
Note - setting the time
• If no DCF radio signal is received within the rst few minutes
of the initial setup procedure, the search is terminated. The
radio symbol disappears.
• In the event of reception problems, we recommend leaving
the clock standing overnight since the interference signals are
generally fewer in number at this time.
• Meanwhile, you can carry out a manual search for the DCF
radio signal at a different location or set the date and time
manually.
• The clock automatically continues to search for the DCF radio
signal daily (01:00, 02:00, 03:00, 04:00 and 05:00). Once
the signal is received successfully, the manually set time and
date are overwritten
If the weather station does not receive the DCF signal, press and
hold the
button (E) for around 3 seconds to start the signal
search for a further 10 minutes. The radio symbol ashes during the
search. If a signal is still not received after that, the time and date
must be set manually.
6.4 Manual setting of the time, date and units
• Press and hold the
out the following settings in sequence:
• 12/24-hour format
• DCF signal ON/OFF
• Time zone (0-12, default "0" for CET)
• Hour
• Minute
• Display "Month/Date" or "Date/Month"
• Year
• Month
• Date
• Language (GE= German, FR= French, IT= Italian, DU= Dutch,
SP= Spanish, DA= Danish, EN= English)
• °C (Celsius) or °F (Fahrenheit)
• To select the individual values, press the arrow buttons
(D) or
(E). Con rm the selection by pressing the
button (A).
• Press the
button (A) to adopt and skip the displayed value.
button (A) for around 3 seconds to carry
• If no entries are made for 20 seconds, the clock automatically
exits settings mode.
Note - time zone
• The DCF signal can be received in many places, however it
does not always correspond to the CET applicable in Germany.
You should therefore remember to take into account the time
(15) ashes
difference in countries with a different time zone.
• Moscow, for example, is 3 hours ahead of Germany. Set the
time to the time zone +3. The clock will then automatically
set itself 3 hours ahead of the time received from the DCF
to
.
signal or the time set manually.
6.5 Maximum and minimum temperature and humidity
values
• The base station automatically stores the maximum and
minimum temperature values in the outdoor and indoor areas.
• Repeatedly press the
temperature to the maximum temperature (MAX) and then to
the minimum temperature (MIN).
• The maximum and minimum temperatures are displayed for
5 seconds.
• While the maximum and minimum values are displayed, you can
also reset these by pressing and holding the
--.-°C and --% brie y appear for the temperature and ambient
humidity. Then the current temperature and ambient humidity
are displayed again automatically.
6.6 Alarm for the maximum and minimum temperature and
humidity values
• Press and hold the
• The temperature display ashes for around 10 seconds. Pressing
the arrow keys
maximum value (HI) and then the minimum value (LO). To scroll
rapidly through the values, hold the arrow key down until the
desired value is reached.
• By pressing the
respective value.
• The sequence is as follows:
Maximum outdoor temperature Minimum outdoor
temperature 
Maximum outdoor humidity Minimum outdoor humidity
Maximum indoor temperature  Minimum indoor
temperature  Maximum indoor humidity  Minimum indoor
humidity
• Once a maximum value is reached, the
ashes next to the corresponding value on the display. Once a
minimum value is reached, the
A 5-second alarm also sounds every minute.
button (D) to switch from the current
button (C) to go to alarm setting mode.
(D) or
(E) allows you to rst set the
button (C) again, you can select the
HI warning symbol
LO warning symbol ashes.
button (D).
5

Publicidad

Tabla de contenido
loading

Tabla de contenido