Technical data

Inlet and Outlet Diameter
Maximum Suction Depth
Maximum Height / Maximum Value of
Total Manometric Height
Maximum Flow
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
WARNING
Before gaining access to the terminals all power sources should be disconnected.

Power Requirements

WARNING
The tool shall be grounded while in use to prevent electric shock.
The hydro pneumatic equipment shall be installed as close as possible to the main
power source. Double check the power supply carries the same voltage than the
voltage indicated in the motor nameplate.
The power supply conductor gauge shall be a minimum 18 AWG. The equipment shall
be set as close as possible to the power supply. In the event the distance is over 10
meters; a higher gauge conductor is recommended (minimum gauge 12 AWG).
CAUTION
Connection to the power source shall be carried out by a
professional electrician, according to figure 1 (see page 6, Power Connection).
• The professional electrician connecting the equipment shall comply with the relevant
mandatory rules.
• The fixed installation shall include a device to assure Omni polar disconnection from
the power source (thermomagnetic switch or fuse).
• Make sure the power requirements described in these manual and in the equipment
nameplate match with the power supply capacity values.
• The hydro pneumatic equipment is built with a single-phase motor protected against
overload It uses a thermal device (due to overload) set in the motor winding.
Using power extension cables is not recommended for hydro pneumatic equipment.
The use of an extension cable causes voltage drop, loss of power in the motor and
overheating.
• In the case the hydro pneumatic equipment is connected to a fuse protected circuit,
use delay action fuses Type "D".
WARNING
All the cabling, power connections and ground connection to the system shall comply with the MEXICAN OFFICIAL
STANDARD NOM-001-SEDE, POWER INSTALATIONS (USE) or with the local codes and ordinances.
Code
Description
Voltage
Frequency
Current
Speed
Services
Tank Capacity
Work Cycle
50 minutes' work per 20 minutes' rest. Daily maximum: 6 hours
Insulation
HIDR-1/2X24
10077
Hydropneumatic Pressure Boosting System
127 V
60 Hz
6.5 A
3 400 RPM
1" x 1"
29.5 ft
11.3 gal/min
4 water connections
6.3 gal
Class I
Power Cord Grips used in this product: Type "Y".
Tool Build Quality: Basic insulation
Thermal insulation on motor winding: Class F
Ground
HIDR-1/2X50
12254
92 ft
6 water connections
13.2 gal
IP Grade
IPX4
Authorized Service Center.
Fig. 1
Pressurestat
Neutral
Feed
Pump
Feed
Line
Feed
ENGLISH
Ground
(Pump)
3