the button. Now all the codes that were saved have been deleted.
The system can learn a maximum of 20 remote controls. If you try to pair
more than that, the D5 LED will flash 5 times to confirm that the maximum
number of remote controls has been reached.
In the remote control learning process, if you press button 1 or button 2 on
the remote control, then button 1 will control the gate in "from car" mode:
open-stop-closed, and button 2 will operate the gate in "pedestrian" mode.
Buttons 3 and 4 have no function.
In the learning process the remote control, if you press button 3 or button
4 on the remote control, then button 3 will control the gate in "car" mode:
open-stop-closed, and button 4 will operate the gate in "pedestrian" mode.
Thus, you can pair the same remote control with 2 automation systems.
13.2 - Obstacle detection
We can set two sensitivity levels: High and Low.
A. High sensitivity: if the gate is opening or closing and encounters a small
obstacle, then the engine will stop.
B. Low sensitivity: if the gate is opening or closing and encounters a large
obstacle, then the engine will stop.
13.3 - Programming
1. OFF position: the engine is in NC mode, Normal Close (default)
ON position: the engine is in NO, Normal Open mode
2. OFF position: photocell is in NO mode (default)
ON position: the photocell is in NC mode
3. and 4 in the OFF position: deactivates the automatic closing function
(default)
3. on the ON position and 4 on the OFF position: when the gate is fully
open, it will close automatically after 10 seconds .
4. on the OFF position and 4 on the ON position: when the gate is fully
open, it will close automatically after 30 seconds.
5. on the ON position and 4 on the ON position: when the gate is fully
open, it will close automatically after 60 seconds.
9
User manual