mundoclima H11 Serie Manual De Instalación Y Usuario página 50

Ocultar thumbs Ver también para H11 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

For
MUEX-21-H11.3
Display
EC 51
Outdoor EEPROM malfunction
EL 01
Indoor / outdoor units communication error
PC 40
Communication malfunction between IPM board and outdoor main board
PC 08
Outdoor overcurrent protection
Outdoor unit low AC voltage protection
PC 10
Outdoor unit main control board DC bus high voltage protection
PC 11
Outdoor unit main control board DC bus high voltage protection /341 MCE error
PC 12
PC 00
IPM module protection
PC 0F
PFC module protection
EC 71
Over current failure of outdoor DC fan motor
EC 72
Lack phase failure of outdoor DC fan motor
EC 07
Outdoor fan speed has been out of control
PC 43
Outdoor compressor lack phase protection
PC 44
Outdoor unit zero speed protection
PC 45
Outdoor unit IR chip drive failure
PC 46
Compressor speed has been out of control
PC 49
Compressor overcurrent failure
High pressure protection
PC 30
Low pressure protection (For MUEX-42-H11.5
PC 31
PC 0A
High temperature protection of condenser
PC 06
Temperature protection of compressor discharge
PC 0L
Low ambient temperature protection
PC 02
Top temperature protection of compressor
EC 52
Condenser coil temperature sensor T3 is in open circuit or has short circuited
EC 53
Outdoor room temperature sensor T4 is in open circuit or has short circuited
EC 54
Compressor discharge temperature sensor T5 is in open circuit or has short circuited
EC 56
Evaporator coil outlet temperature sensor T2B is in open circuit or has short circuited
EC 50
Open or short circuit of outdoor unit temperature sensor (T3,T4.T5)
,
MUEX-27-H11.3
,
MUEX-42-H11.5
(For MUEX-42-H11.5
LED STATUS
)
)