Select Option 2 from the MENU. Press LEARN button until 2 beeps sound
1.
(maneuver time programming mode has been activated).
The door will start the opening maneuver. If limit switches have been
2.
selected, maneuver will stoponcelimit switchesare activated, if not, the order
must be given by you at the end of the maneuver.
Once opening maneuver finishes, control board awaits foran order to start
3.
closing maneuver. If activated within 5 seconds, manual mode will be
activated; if activated after 5 seconds, automatic closing mode will be set
up and thetime elapsed from the end of opening tothe start of the closing
maneuver will be programmed as stand-by time.
*In case photobeam is DISABLED (DIP 4 ON): Automatic closure is not
available at programming maneuver option from the menu (dueto
security reasons).
*In case photobeam is ENABLED (DIP 4 ON) but not installed by the user:The
control board will block itself and no closure maneuver will be allowed,
showing to the user there is a mistake and its programmation.
The door will only stop by pressing the limit switches when these are installed.
4.
Then, 1 beep will indicate the end of the closing maneuver and the exit from
the timing programmation.
Repeat the procedure if you need to modify the programmation.
Attention: O/S/C button activates function OPEN/STOP/CLOSE.