Parts
Start Up
Cartridge Loading
The pneumatic tool must not be connected to the air supply, to prevent it from being
CAUTION
accidentally triggered during the process.
• Push back the cartridge lock (A) until it is secured at
the end of the cartridge.
• Insert the nails into the cartridge track by resting
them in the cartridge lock (B).
CAUTION
Make sure the nails are not
dirty or damaged.
• Release the cartridge lock to push the nails
to the tip of the tool.
Air Supply Connection
• Connect the hose to the compressor and let some air
flow through the hose and quick coupling to verify that
both are clean before connecting them to the tool.
• If you do not have an oil filter as recommended on
page 3, apply a few drops of tool oil to the air inlet (C).
• Connect the air hose to the tool using the quick
CAUTION
coupling (D).
hose to the tool, make sure the nail cartridge is empty.
• The quick coupling is useful to quickly connect and
disconnect tools and to exchange them easily.
Air
intake
cartridge
Before connecting the
Handle
Trigger
Depth
Regulator
Nails
A
C
Air
Outlet
Cartridge
lock
Contact
lock
C
B
D
ENGLISH