Main exchanger replacement
Before carrying out the following instructions it is advisable to protect the room and the
A
boiler's electrical box against accidental water spillage.
Disconnect the power supply and close the gas cock
B
ahead of the valve
• Disconnect the fume sensor connector 1.
• Disconnect the fan connector
• Disconnect the connector of the ignition
electrode connected to the board.
• Drain the water from the boiler heating
circuit.
• Remove the flue connection (concentric
or accessory for separate ducts)
• Remove the fan
• Remove the clips of the two pipes on the
exchanger, pump and hydraulic unit
• Loosen the 2 bottom screws "5" secur-
ing the exchanger to the frame (fig. 48)
• Remove the 2 top screws "6" securing
the exchanger to the frame (fig. 49)
• Remove the exchanger
326
EN
• Insert the new exchanger, resting it on
the bottom screws "5"
• For assembly, proceed in reverse order
fig. 45
fig. 46
cod. 3541V512 - Rev 00 - 07/2022
ALHENA TECH C