Enerco H100 Instrucciones De Funcionamiento Y Manual Del Propietario página 11

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Correct
Wrong
Figure 10
Connection Pipe & Chimney Connection
LINED MASONRY CHIMNEY INSTRUCTIONS &
DIAGRAM
This stove is designed to be vented through a masonry
chimney with flue liner (clay tile which protects
chimney) which conforms to local building codes, fire
codes, and latest edition of NFPA 21 1 US or CAN/
CSA-B365.
1. Clean the code-approved lined masonry chimney
2. Inspect the lining of the chimney and make any
required repairs.
3. If the connection piping from the stove to a
masonry chimney is made through a combustible
wall, consult a qualified mason or chimney dealer
for consultation. To ensure safety, the installation
should only be done by a qualified installer. The
installation must conform to the regulations
established by local fire codes and building codes.
THIMBLE
COLLAR
6" ROUND
24 ga. BLACK
CONNECTOR
STOVEPIPE
LINER
BELOW
ENTRY
HOLE
Figure 11
Connection to Masonry Chimney
If there is an opening at the base of the chimney it
must be closed tightly.
Wood Fire Stove
MANUFACTURED CHIMNEY INSTRUCTIONS &
DIAGRAM
WARNING: DO NOT USE SINGLE-WALL
CONNECTION PIPE AS A CHIMNEY.
This stove is designed to be used with either a UL
103 or ULC S629 (CAN) listed manufactured chimney
Wrong
or an approved UL-1777 (US)/ULC S635 or ULCS640
(CAN) lined masonry chimney. Not all manufactured
chimney are UL 103 or ULC S629 (CAN). Home centers,
hardware stores, HVAC supply stores, and the Online
websites of chimney manufacturers will be able to
provide stove pipe that is rated to these standards.
This listing indicates that the Chimney is rated for high
temperatures up to 2100˚F (1149˚C).
Only use components that all come from the same
manufacturer. Do not mix brands of components for
the same ventilation system.
The following figures illustrate various methods and
requirements of using a manufactured chimney and
connection pipes to vent the wood stove.
CHIMNEY
FLUE
5/8" TILE
CHIMNEY
LINER
MASONRY
CHIMNEY
Figure 12
E1 1
Manufactured Chimney through Roof
Operating Instructions and Owner's Manual

Publicidad

Tabla de contenido
loading

Tabla de contenido