7 Installing the device

7.1 Mounting the device

A
NOTICE! Damage hazard
The controller warms up during operation. Make sure it is installed on a non-flammable
surface.
I
NOTE
The controller and battery must be installed in the same room.
1. Drill 4 holes.
2. Mount the controller with appropriate fasteners.
7.2 Choosing proper wires and fuses
A
NOTICE! Damage hazard
For proper operation of the charging system, choose the size of wires between the
solar panel and the battery carefully.
A
NOTICE! Damage hazard
Do not exceed wire length of 7.6 m from solar panel to the battery.
Solar panel
50 W
80 W
100 W
160 W
200 W
300 W
400 W
A
NOTICE! Damage hazard
Install an in-line fuse as close to the positive battery terminal as possible. This installation
prevents any damage to the connected devices in case of excessive current.
EN
Gauge
#14 AWG - 1.6 mm
#12 AWG - 2 mm
#10 AWG - 2.6 mm
#10 AWG - 2.6 mm
#10 AWG - 2.6 mm
#8 AWG - 3.3 mm
#8 AWG - 3.3 mm