Function Test; Low Battery Warning - Hiltron security XR Serie Instalación

Detector a infrarrojo pasivo vía radio
Ocultar thumbs Ver también para XR Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

XR8 - Passive infrared radio XR Series detector
INSERTING OR REPLACING THE BATTERY
After removing the old battery, press and hold the centre button for 5 seconds; then release it and
insert the new battery, checking that the two LEDs light-up instantaneously. If not, repeat the process
keeping the right button pressed for a little longer.
To stabilise the sensor circuit, wait 60 seconds, during which the green LED will flash intermittently.
The XR8 is then ready for use.
PROGRAMMATION
Press and hold the two buttons until both LEDs are lit, then release.
Enter the zone code using the inferior button for one (S2) and the superior button for zero (S1)
Zone 2:
0 0 0
Zone 3:
1 0 0
Zone 4:
0 1 0
Zone 5
1 1 0
Zone 6
0 0 1
Zone 7
1 0 1
Zone 8
0 1 1
Zone 9
1 1 1
Then enter the 18-digit terminal code, checking that the
Green LED lights up for one (S2,inferior button) and the red LED for zero
(S1,superior button).
If the configuration is successful, the two LEDs
Will light up instantaneously.
Attention : if you enter a terminal code containing a sequence of all ones or all zeros, the XR6 will produce an
error signal and both LEDs will flash simultaneously to indicate an error.
SENSITIVITY SETTING
Press and hold the S2 button of the XR8 for a few seconds until the red LED lights up, then release it. The
green LED will light up each time the sensor detects movement, but will not trigger the alarm on the base unit.
This allows you to set the device to the desired sensitivity (turn trimmer clockwise to increase sensitvity); for a
reliable configuration, make sure to replace the cover each time it is changed and ensure that the lens is
positioned correctly on the pyroelectric sensor.
To interrupt the test phase, press both buttons simultaneously until both LEDs light-up; otherwise, wait
until the test is completed (5 minutes).

FUNCTION TEST

Press and hold the superior button S2 for a few seconds until the green LED lights up; this will start the
sensor test phase, and enables the XR series to send signals to the base unit.
During this phase, the transmission interval time (5 min.) is deactivated and the sensor transmits at each
detection. To interrupt the test phase, press both buttons simultaneously until both LEDs light-up; otherwise,
wait until the test is completed (5 minutes).

LOW BATTERY WARNING

Each time the contact is opened::
Green LED: working correctly
Red LED: battery empty
4
+
System code
+
System code
+
System code
}
+
System code
+
System code
+
System code
+
System code
+
System code
XR500 anti-theft central
unit will not recognize
these zones because it
handles up to 3 zones via
radio.
security
S1
S2
S3
Sensitivity setting
Tamper

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Xr8

Tabla de contenido