• Power on/off: short press the power button, the LCD screen will be automatically lighted up. Long press the
power button, it will be power off. When power on, if no more operation in 25 seconds, it will be power off
automatically.
• Pressure preset:
A. Air pressure unit switching: After the product turn on, short press +/- button, the air pressure unit (PSI, Bar,
KPA, Kg/cm²) can be switched.
B. Air pressure target setting: After setting the air pressure unit, long press +/- button, the LCD screen will be
fl ashing status, you can press the +/- button to perform the target air pressure setting.
C. After setting the target air pressure number, long press the power button to exit or wait 3 seconds, it will
automatically exit.
D. Quick set the infl ation mode: short press "M" button to quickly set the infl ation mode, which can be respecti-
vely set as:
E.
System default pressure: 0.85BAR;
F.
System default pressure: 3.5BAR;
G.
System default pressure: 2.2BAR;
H.
System default pressure: 2.2BAR;
J.
System default pressure: 2.3BAR;
Air pressure detection and infl ation:
A. After the setting is complete, connect the air hose into the compressor exit and the device that needs to be
infl ated. The device will automatically detect the current pressure of the connected product and display the data
on the LCD screen.
B. Press the power button, the air pump starts to infl ate, and it will automatically shut down when the preset
pressure value reached, long press the power button to be power off, then remove the air hose and the infl ation
is completed.
LED lighting on/off:
A. Long press the (12) button on the battery pack, white LED lighting, when the white LED lighting, short press
the (12) button, the white LED turn off, the blue/red light fl ashing slowly at the same time, short press in the (12)
button again, blue/red lighting fl ashing fastly. Long press (12) button again, turn off all lights.
Charging the Battery
- The lithium batteries may lack performance and charge if they are not properly charged. Only recharge the
batteries when the tool lacks performance. Do not recharge the batteries with half load or which have not been
completely discharged.
- The useful life and performance of the battery may be improved if the charging is performed when the tempera-
ture is between 18 °C and 24°C. Do not charge the battery in extreme temperatures (below 0°C and above 40°C).
- The charger's DC output plug in to the battery case, and the power head plug into 100-240VAC power socket.
The charger indicator light turns to red, after full charged, the indicator light turns to green.
- In order to charge the battery, plug the battery charger into and electrical outlet and then fi t the battery into it.
- When the tool performance is lacking, recharge the battery;
- It is not recommended to charge the battery when it heats up during operation and it is still hot. Wait for the
battery to cool down before charging it; that will extend its useful life;
- If, after the charging, the performance of the tool is still lacking, that means the battery is not able to perform
chemical reactions for its charging anymore. If that occurs, the battery must be replaced.
-Remove the battery case: refer to the below photo: