ENGLISH
INSTALLATION GUIDE
Indicator Light
The Acuva logo lights up to indicate various modes of use.
No Light: The device is idle or no power is connected.
Blue Light: The device is active and disinfecting water.
Green Light: The device is undergoing its self-cleaning protocol. This 30 second protocol occurs at
start up as well as after every 12 hours of idle time and can be safely interrupted to dispense water.
Note: If there is a fault, the indicator light will turn red or yellow. Please consult the Troubleshooting section.
The Acuva Wanderer
of-the-art UV-LEDs, meaning there are no mercury bulbs to replace. However, there are some simple
tasks that should be performed to ensure continued operation.
MAINTENANCE
Regular Maintenance
1. Check monthly that none of the connectors are leaking.
2. Replace the in-line filter after winterization or as per the instructions on the filter label.
Note: The small quartz windows inside the unit does not reach high temperatures to encourage
mineral build-up (scaling) as with UV lamp systems. As a result, no significant scaling or loss of
performance due to scaling over time is expected.
Winterizing
HOW TO WINTERIZE YOUR UV-LED WATER PURIFICATION SYSTEM:
1. Remove the Pre-Filter
Remove the pre-filter from the system and set it on its end (outlet-down) to drain. Place the filter in
a bag and store in a refrigerator or a cool environment until it's time to flush and use it again.
2.
OPTION A) Apply Compressed Air
Apply compressed air to the inlet of your unit to blow out any and all water trapped in the system
as well as any accessories such as flow restrictors or faucets you may have. Repeat this a few
times to ensure no water is left in the lines.
OPTION B) Use Antifreeze Reagent
Follow your RVs owners manual to drain out your water lines and run special RV antifreeze
through the system.
OPTION C) Remove and Store Away
If you do not have access to compressed air or antifreeze, remove the system and flow restrictor (if
present) and store in a temperature controlled environment >4°C (>39.2°F) until ready to re-install.
Note: Simply draining your water system may not be effective at removing enough water to prevent damage
inside the device.
10
REV: 08.19.22 | CCD-00066465
2.0 is designed to give years of trouble-free use. Acuva products use state-
TM
Acuva Wanderer
2.0 User's ManUal
TM