ENGLISH
INSTALLATION GUIDE
Acuva Wanderer
1. Find an under-counter position for the Acuva Wanderer
space for all tubing to be connected without needing to bend to the point of pinching or folding.
2. Mount the DIN-rail (shown in the "Mounting the Unit" diagram) that will support the device with
two #10 wood screws and the filter clip(s) (item no. 3) for the pre-filter with the two remaining screws.
NOTE: The filter may have one or two mounting clips
3. Install the ½" PEX to 1/ 4 " OD Tee & shutoff valve (item no. 1) to the cold-water line, ensure the cold-
water line is not under pressure by turning off the water and/or cutting the flow with an upstream valve.
Expect some water to drain from the cold-water line while cutting it. Insert the ½" cold-water lines
to the ½" female ends of the Tee, pushing the tubes into the Tee as far as possible and pulling
gently to assure that the seal is secure.
4. Cut a length of ¼" tubing (item no. 2) that will connect the Tee to the pre-filter (item no. 4). Feed the
compression nut and brass ferrule over the tubing, and insert the tubing into the tee. Use a
wrench to firmly tighten the compression nut until the tubing stays in place when pulled.
5. Remove the protective caps from both ends of the filter by first removing the safety stops then
pulling the caps off. Connect the 1/ 4 " tube from the Tee into the inlet side of the pre-filter while
making sure that water will flow in the proper direction as indicated on the filter. Push the tube
into the filter as far as possible and pull gently to ensure it is properly sealed. Snap the pre-filter
into its wall-mounted clip(s).
6. Install Acuva Wanderer
the Unit" figure.
7. Cut a length of the 1/ 4 " tubing that will connect the pre-filter to the Acuva Wanderer
and push both ends of the tubing into place, and pull on each gently to ensure it is properly sealed.
8. Cut a length of the 1/ 4 " tubing that will connect the device and the output faucet or appliance, and
install the flow restrictor (item no. 6) at a point along the tube that is convenient – noting the flow
direction of the restrictor. Connect the tubing to the desired water faucet or appliance. For each
push-fit connection, pull the tubing gently after installation to ensure it is secure and sealed.
Note: Please use Teflon tape sealant (or other appropriate sealants) on all threaded fittings and connections.
For faucet installation instructions, see Appendix A.
8
REV: 08.19.22 | CCD-00066465
2.0 Installation
TM
2.0 (item no. 5) by mounting it to the DIN-rail as seen in the "Mounting
TM
2.0 and pre-filter to be mounted, allowing
TM
Acuva Wanderer
2.0 User's ManUal
TM
2.0's inlet
TM