Descargar Imprimir esta página

Alice's Garden ARCTIC PCG230KD Manual De Instrucciones página 38

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20
EN
ADVICE IN CASE OF FAILURE
PROBLEM
The pilot light
does not turn on
The pilot light
does not stay lit
The burner does
not light
The flame of
burner is weak
Note : do not turn
on the device
when the tem-
perature is lower
than 5˚C
The flame of
burner is not
Uniform.
Note : the bottom
2.5 cm part of the
burner should not
have a flame.
Carbon accumu-
lation
Thick black smoke The burner is clogged
38
REASON
The safety/reset button on the pressure
regulator has not been pushed.
The valve of the gas set point is closed /
Gas bottle is empty
Pilot flame orifice or tube is jammed
There is air in the gas line
Gas pressure is low
The piezo igniter does not work
Accumulation of dirt around
the pilot light
The connection between the gas
valve and the pilot is loose
The thermocouple is not working
correctly
Gas pressure is low
The orifice is blocked
The switch is not on
the «HI» or «LO» position
Gas pressure is low
Outside temperature
is greater than 5˚C and the cylinder
is ¼ full
The supply hose is folded or
twisted
The switch is not on
the «HI» or «LO» position
Gas pressure is low
The base is not on a flat surface
Accumulation of dirt on the burner
Dirt or cover on the reflector
and the transmitter
SOLUTION
Press the reset button on the regulator to start
the gas supply
Open valve / Replace set point - Pilot orifice or
tube is blocked
Clean the pilot orifice or tube with a brush or
using a brush or a paintbrush
Open and purge the gas line (keep the switch
pressed on PILOT) for 1 within 2 minutes or until
you detect a slight smell of gas
Replace the setpoint
Use a match to light the pilot light (next page).
If it lights up, get a new igniter and replace it
Clean the dirt around the pilot light
Tightened the connection and check for leaks
Replace the thermocouple
Replace the gas cylinder
Clean the orifice
Turn the button to the «ON» position
Replace the gas cylinder
Replace the gas cylinder
Untwist the hose and check there are no
leaks.
Turn the knob to the off position
(«OFF»), let the appliance cool down and
make sure that the burner and the orifices
are not blocked
Replace the gas cylinder
Place the heater on a levelled surface
Clean the burner.
Clean the reflector and the transmitter
Turn the knob to the off position
(«OFF»), let the appliance cool down,
remove the cover and clean the inside and
outside burner
29/06/2022

Publicidad

loading

Este manual también es adecuado para:

Arctic pcg230kdgc