Descargar Imprimir esta página

BS BATTERY BST 1000 Manual De Usuario página 9

Ocultar thumbs Ver también para BST 1000:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 25
3. Charging test result: High
Generator output volt is high. Since most of the vehicle generators are using internal
regulator, the generator assembly has to be replaced.(Some old style cars are using
external regulator, then directly replace the regulator.).
The normal high volt of the voltage regulator is maximum 14.7±0.5V. If charging volt is
too high, it will overcharge the battery. Therefore the battery life will be shortened and
troubles will be caused.
4. No Volt Output:
No generator volt output is detected. Check the generator connection cable and the belt
whether they are normal.
5. Diode Test:
Through the test of charging current ripple, tester will find out whether the diode is normal
or not. When ripple volt is too high, it proves at least one diode is damaged. Check and
replace the diode.
REVIEW DATA
Choose the function of Review Data and review the history of battery testing result.
Healthy: 96% 490A
Charge: 98% 12.64V
Internal R= 6.3mΩ
Rated: 500A CCA
Battery OK
9
| www.bs-battery.com

Publicidad

loading