ASSEMBLY INSTRUCTIONS
5. Wire connection guide:
Ground wire:
• For installation in the United States: Wrap
ground wire from outlet box around ground
screw preassembled on mounting bracket
(B) no less than 2 in. from wire end. Tighten
ground screw. If fixture is supplied with a
ground wire, connect to outlet ground wire
with a wire connector (AA).
• For installation in Canada: If fixture is
supplied with ground wire, wrap ground wire
around ground screw on mounting bracket
(B). Tighten ground screw. Connect fixture
ground wire to outlet ground wire with the
wire connector (AA).
Supply wires:
• Connect the Neutral (White) supply wire from
the outlet box to the Neutral fixture wire
(White).
• Connect the Hot (Black) supply wire from the
outlet box to the Hot fixture wire (Black).
Hardware Used
Wire Connector
AA
6.
Mounting surface should be clean, dry, flat
and 1/4 in. larger than the canopy (A) on all sides.
Any gaps between the mounting surface and
canopy (A) exceeding 3/16 in. should be corrected
as required. With silicone caulking compound (not
included), caulk completely around where back of
canopy (A) meets the wall surface to prevent water
from seeping into outlet box.
5
BARE COPPER,
OR GREEN
GROUND
SUPPLY WIRE
BLACK SUPPLY
WIRE
WHITE SUPPLY
WIRE
x 3
3 6
6
BARE COPPER,
AA
OR GREEN
GROUND
FIXTURE
WIRE
BLACK FIXTURE
WIRE
WHITE FIXTURE
WIRE
A