Pump WaterVISE, FloVISE
Installation
We recommend using the Pahlén connection Kit (article number
118000), which contains Unions with O-ring seal.
Use threaded tape or thread sealant for ABS plastic when tightening the
threads.
Pipe connection are made BEFORE electrical installation.
Dimension the pipes as per the table below.
Use the given small rubber mats under the feet of the pump to prevent
structure-borne sounds.
WARNING
• The pump must be placed lower than the pool's water surface and near the pool in order to
get as short suction pipe as possible.
• Free distance behind the pump motor must be at least 2.5 X fan diameter.
• Fix the pump with a suitable bolt in a steady, level base in a way that structure-borne sound
is prevented.
• Make sure that the space has good ventilation, is dry and there is no risk of drowning.
• The pump with the pre-filter must be placed such that the strainer bucket can be lifted out
for regular cleaning/draining.
Alternative inlet direction
The pre-filter housing is divisible and the upper part can be turned and
mounted in 7 different inlet directions. This makes it easy to adjust
placing the pump in the machine area with regard to piping of the pool
system.
Do the following to change the inlet direction:
1. Loosen the 8 screws (G) that secure the upper part (hexagon 5).
2. Lift up and turn the upper part to the desired position.
Make sure the o-ring (F) is correctly positioned in its groove.
3. Attach the upper part with the 8 screws (with washers below).
Screw them firmly (4 Nm).
Installation pipe
Piping to and from the pump must be clamped or backed up to discharge. This is to prevent material stresses that can lead to
damage and / or leakage.
Do not use fast-closing valves as they can generate pressure shocks that exceed the maximum pressure of the pump.
Check that all connections are completely sealed during commissioning.
1
2
6
Installation
4
5
5
7
R
10
Min 8 x ØA
G
H
3
1. Skimmer
2. Bottom outlet
3. Inlet
4. JetSwim
9
5. Lighting
6. Pump
7. Filter
8. Electric heater
8
9. Check valve
10. Sewage
File: M12548-0
2016-10-18 ASA
12
ENGLISH
Min 2,5 x ØB
Picture 5
Picture 6